Autoclave (Small Type)

 

IR-PC-300-400H 


Purpose

  • For reliability testing of sanitary ware
  • Equipment manufactured based on KS standard testing specifications.


Feature

  • An equipment used to test the strength of sanitary ware by applying pressure and temperature.
  • Equipment manufactured based on KS standard testing specifications.
  • PID Auto-tuning controller
    Able to find the optimal PID values according to the surrounding environment for precise temperature control. Digital LED or LCD(Option)
  • Interlock system - A safety mechanism that automatically defends itself to prevent further experimentation in case of artificial or natural malfunctions or errors.
  • Fail safe - In case of a malfunction, if there is an issue with the safety operating device, the power supply to various parts is automatically cut off, and the system remains in a standby state with only the grounding part connected. This feature enhances user safety by protecting against potential hazards.


Specification

 Volume
50L(including the bottom plate)
 Temperature Range Amb ~160℃
 Controller Touch screen controller, Data backup available
 Pressure RangeDesign: 20bar /
Working: 1~10bar
 Distribution ±0.5 bar
 Material Chamber  Stainless Steel 304
 Body SS40, 1.2T
 Sensor  K-Type
 Insulation  Ceramic Wool KCC
Door Gasket
 Heat Resistance Silicone (Packing spare 1ea)
Safety Door- Door cannot be opened during operation
- Operation is not possible before the door is securely locked
 Basket 1ea, To be proceeded after discussion
 HeaterHeating Type
 SUS  Heater
 Capacity 7~8KW Separate heater at the bottom
~ KW (Subject to change depending on usage conditions)
 Size (W x D x H) mm Internal  300Ø x 400L mm
 External  900W x 1200D x 1500H
(Subject to change based on design.)
 Power
Consumption
 220V 3P 60Hz, 10kW, 50A 이내
(It may vary depending on the specifications.)
 WarrantyDuration
1 year
 Safety Device Overtemperature, overpressure protection, and heating cutoff device.
Door opening prevention device during operation, dual-door locking mechanism





The status of the equipment can be checked through the tower lamp's color.

1) RED : Malfunction

2) YELLOW : Standby

3) GREEN : Operating


Drain control valve: Allows adjustment of drain flow









  1. Main Power
  2. Controller
  3. Heater
  4. Pressure
  5. Reset
  6. Packing
  7. Emergency stop
  8. Supply pressure gauge
  9. Water in
  10. Manual vent
  11. Air
  12. Water out
  13. Drain


Terms of Use  |  Privacy Policy