Multi-Room Vacuum Oven

 

VO-196S 


Purpose

  • It is suitable for use in production environments with limited space.  




Feature

  • Suitable for use in production environments with limited space.
  • Features the ability to control the temperature in each room individually.
  • These products are used by electronics, electrical components, and chemical companies.
  • The product's door is made of aluminum instead of glass.
  • Excellent stability with an O-ring type design, which reduces the load on the O-ring, ensuring long-term use. It provides a great sealing effect and is highly efficient in maintenance.




Specification

 ModelVO-196S 
 Environment ConditionTemp. 5℃~ 35℃ Maximum Relative Humidity 85%RH  Altitude up to 2,000m
 Chamber Volume (ℓ)196L
 Heater Power (kW)6.5kW
 Temperature Range Abm. 45℃~250℃(Recommended up to 220°C)
Control  0.1℃ 
Accuracy ±2℃ at 100℃ 
 ControllerDigital PID control system 
 SensorK-type
 Stability±1.0℃ 
 Heat up Time200℃ within 100 minutes (only chamber empty status) 
 Vacuum Range 0~760 Torr analog type
 Degree About 0.1 Torr
 Material InteriorStainless Steel 
 Exterior Steel, 1.2t, Double Painted & Baked
 Heater SUS Pipe Heater
 Insulation Mineral Wool (100mm)
 Door packing Molded Heat Resistant Silicone Rubber
 Inner glass Tempered Safety Glass, 15mm
 Heating MethodSUS Sheath Heater  1kW x 3 EA / 500W x 7EA 
Shelf3 EA 
Dimension Internal 402 405 1606 
External600 710 1906 
Power220V / 3P/ 60Hz 3.5kW 
Weight (kg) about 80kg 



Product Advantages 

  • The product is equipped with a viewing window, allowing you to check the samples frequently.
  • The center of gravity is positioned towards the front, so the wheels are placed at the front. => making it easier to move.
  • Its compact structure allows multiple units to be used in a small space.
  • When there is limited space, the product can be very useful and efficiently utilized in narrow areas.




How to Use

  • The product is divided into three sections inside. 
  • Place the samples in each of the three sections, set the temperature, and turn on the pump to create a vacuum.
  • Once the vacuum is applied, impurities and moisture in the samples are expelled, and the product is used in the final stage of processes for electrical and electronic products.
  • Since it is a multi-room chamber, it allows for temperature control in three separate areas.
  • When the timer is used, the heater will turn off once the timer reaches zero.
  • When not in use, the heater will remain on unless manually turned off.
  • After the work is complete, turn off the pump and open the vent valve to release the vacuum and open the door.
  • To fill the nipple with gas, open the vent valve and then add the gas.