 | | RVO-20
Purpose - The rotating performance of the chamber consistently brings great quality in drying materials.
|
Feature
Stable vacuum maintenance & safe door structure
- PID Auto-tuning controller
Automatically adjusts PID values according to the surrounding environment, enabling precise temperature control. Digital LED or LCD (Option). - Interlock System - In the event of artificial or natural errors or malfunctions, the safety system automatically prevents the experiment from continuing, providing self-defense.
- Fail safe - In case of a malfunction, the safety operation device automatically cuts off power supplied to various parts and remains in standby mode with only the grounding connected. This feature enhances user safety by protecting against potential hazards.
- The rotating parts and components are specially designed to be used at high temperatures, and safety is enhanced by using louver heaters and insulation materials inside the chamber to prevent injuries caused by heat transfer.
|
Specification
| Model | RVO-20 |
| Electrical Requirements | 220V / 380V 60Hz 3P |
| Temperature Range | 45 ~ 250℃ |
| Temperature Control / Stability | 5℃ (±10℃) |
| Vacuum Degree | Down to 5 To At empty |
| Controller | PID Controlled microprocessor touch pad & Digital Display |
| Overall Dimension (mm) W x D x H | 1800 x 910 x 1900 |
| Chamber | External | 320 x 390∮ |
| Internal | 260 x 280∮ x 20L |
| Chamber Material | Stainless Steel |
| Note | Program Controller, Cold trap bath (Option) |
※ Chiller / Cold trap / Vacuum pump / Purge Heater are optional accessories.
※ Size and other specifications are always negotiable with clients' demand.
Vacuum Range Options
10-^3Torr or higher is also available.
Reference
 | - Clamp is used for better sealing.
- CERAKWOOL insulation is applied in the chamber.
* A flow guide is installed for well-circulation in it. |
 | * Foot Master - prevents from slight shaking of the equipment and it is easily fixable. |
RVO-20
Purpose
Feature
Stable vacuum maintenance & safe door structure
Automatically adjusts PID values according to the surrounding environment, enabling precise temperature control. Digital LED or LCD (Option).
Specification
※ Chiller / Cold trap / Vacuum pump / Purge Heater are optional accessories.
※ Size and other specifications are always negotiable with clients' demand.
Vacuum Range Options
10-^3Torr or higher is also available.
Reference
- Clamp is used for better sealing.
- CERAKWOOL insulation is applied in the chamber.
* A flow guide is installed for well-circulation in it.